49 resultados para INSTRUMENTS

em Indian Institute of Science - Bangalore - Índia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new liquid crystalline phase, induced by the addition of small amounts of a non-mesogenic solute (such as dimethyl sulphoxide or methyl iodide) to a quaternary ammonium salt, N-methyl-N,N,N-trioctadecylammonium iodide (MTAI), has been detected by NMR and optical microscopic studies. In some cases, there is a coexistence of nematic and smectic phases. Information on the ordering of the phases in the magnetic field of the spectrometer has been derived from NMR spectra of a dissolved molecule, C-13-enriched methyl iodide. The low order parameter of the pure thermotropic nematic phase of the salt provides first-order spectra of the dissolved oriented molecules. Analyses of spectra of cis,cis-mucononitrile exemplifies the utility of the MTAI nematic phase in the determination of structural parameters of the solute.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experiments in spintronics necessarily involve the detection of spin polarization. The sensitivity of this detection becomes an important factor to consider when extending the low temperature studies on semiconductor spintronic devices to room temperature, where the spin signal is weaker. In pump-probe experiments, which optically inject and detect spins, the sensitivity is often improved by using a photoelastic modulator (PEM) for lock-in detection. However, spurious signals can arise if diode lasers are used as optical sources in such experiments, along with a PEM. In this work, we eliminated the spurious electromagnetic coupling of the PEM onto the probe diode laser, by the double modulation technique. We also developed a test for spurious modulated interference in the pump-probe signal, due to the PEM. Besides, an order of magnitude enhancement in the sensitivity of detection of spin polarization by Kerr rotation, to 3x10(-8) rad was obtained by using the concept of Allan variance to optimally average the time series data over a period of 416 s. With these improvements, we are able to experimentally demonstrate at room temperature, photoinduced steady-state spin polarization in bulk GaAs. Thus, the advances reported here facilitate the use of diode lasers with a PEM for sensitive pump-probe experiments. They also constitute a step toward detection of spin-injection in Si at room temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A systematic study of Ar ion implantation in cupric oxide films has been reported. Oriented CuO films were deposited by pulsed excimer laser ablation technique on (1 0 0) YSZ substrates. X-ray diffraction (XRD) spectra showed the highly oriented nature of the deposited CuO films. The films were subjected to ion bombardment for studies of damage formation, Implantations were carried out using 100 keV Arf over a dose range between 5 x 10(12) and 5 x 10(15) ions/cm(2). The as-deposited and ion beam processed samples were characterized by XRD technique and resistance versus temperature (R-T) measurements. The activation energies for electrical conduction were found from In [R] versus 1/T curves. Defects play an important role in the conduction mechanism in the implanted samples. The conductivity of the film increases, and the corresponding activation energy decreases with respect to the dose value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A high speed digital signal averager with programmable features for the sampling period, for the number of channels and for the number of sweeps is described. The system implements a stable averaging algorithm (Deadroff and Trimble 1968) to provide a stable, calibrated display. The performance of the instrument has been evaluated for the reduction of random noise and for comb-filter action. Special uses of the instrument as a box-car integrator and as a transient recorder are also indicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We describe an X-band ESR cavity for angular variation studies on single crystals at room temperature. The cavity was found to have a high Q over wide rotation angles. Review of Scientific Instruments is copyrighted by The American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract is not available.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method of ion extraction from plasmas is reported in which the interference of field lines due to the extraction system in the plasma region is avoided by proper shaping of the extractor electrode and is supported by field plots.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A locked high-pressure cell with working pressure range up to 10 kbars suitable for low-temperature studies to 77 K has been described. It can be used for both EPR and NMR studies of single crystals (and other solid samples). The high-pressure seal and all other aspects of the cell remain the same for either application. Only a change of the bottom plug is required for a switch from a nuclear-magnetic-resonance (NMR) to an electron-paramagnetic-resonance (EPR) experiment. Details of the procedure for the calibration of pressure inside the cell at various temperatures are discussed. The performance of the cell in EPR (Cr3+ion) and NMR (27Al nucleus) studies is reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An inexpensive and simple circuit to aid the direct measurement of majority carrier capture cross sections of impurity levels in the band gap of a semiconductor by the variable width filling pulse technique is presented. With proper synchronisation, during the period of application of the pulse, the device is disconnected from the capacitance meter to avoid distortion of the pulse and is reconnected again to the meter to record the emission transient. Modes of operation include manual triggering for long emission transients, repetitive triggering for isothermal and DLTS measurements and the DLTS mode which is to be used with signal analysers that already provide a synchronising pulse for disconnection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A set of coils has been designed and constructed for generating magnetic field gradients for a Faraday magnetometer. We have obtained a gradient of magnitude -1 1 kOe m-' (8.75 x lo5 A m-') in an air gap of 42 mm for a current of 12 A passing through the coils.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is shown that cholesteric liquid crystal mixtures can be used as convenient solvents in NMR experiments for the determination of molecular structure. The advantages of such solvents are pointed out. The application is demonstrated for acetonitrile; the value for the HCH bond angle thus determined is 108.8°.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a recent paper, Srinivasan et al (1980) have described a programmable digital signal averager with facility for programming the sampling period, number of channels and number of sweeps. We have examined this paper in some detail and find that some points need clarification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple four-terminal AC bridge is described which can be used with germanium resistance thermometers down to 1 K. The special features of the bridge are its ease of fabrication and extremely low cost.